Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-06-15 to 2016-10-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7100 (Viscosity)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Standard covering the apparatus used:
The viscosity of the test item was determined at 20°C and 40°C using a glass capillary viscometer (Tamson Instruments, Bleiswijk, The Netherlands).
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Batch no. 41251
- Expiration date of the lot/batch: 2017-03-01 (taken from Label)

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature
- Stability under test conditions: until 01 March 2017 (nominal expiry date) (taken from label)

FORM AS APPLIED IN THE TEST (if different from that of starting material): Colourless liquid
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 0.51
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 0.39

Viscosity of the test item

Temperature

[°C]

Test

Calibration constant

[mm2/s2]

Flow time

[s]

Kinematic viscosity

[mm2/s]

Mean

[mm2/s]

20

I

0.00106

479.5

0.508

0.51

II

0.00112

453.4

0.508

 

40

I

0.00106

367.9

0.390

0.39

II

0.00112

347.3

0.389

Conclusions:
The kinematic viscosity of the test material (AsahiklinTM AC-2000) was 0.51 mm2/s at 20°C and 0.39 mm2/s at 40°C.
Executive summary:

The viscosity of AsahiklinTM AC-2000 was determined using a glass capillary viscometer.

The kinematic viscosity of the test material was 0.51 mm2/s at 20°C and 0.39 mm2/s at 40°C.

Description of key information

The viscosity of 1,1,1,2,2,3,3,4,4,5,5,6,6-tridecafluorohexane was determined using a glass capillary viscometer. The kinematic viscosity of the test material was 0.51 mm2/s at 20°C and 0.39 mm2/s at 40°C.

Key value for chemical safety assessment

Viscosity:
0.51 mm²/s (static)
at the temperature of:
20 °C

Additional information

A GLP-compliant study, conducted according to OECD Guideline 114 (capillary viscometer (static)) was provided for 1,1,1,2,2,3,3,4,4,5,5,6,6-tridecafluorohexane (Charles River Laboratories Den Bosch BV., 2016a).