relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing conducted between 16 May 2008 and 02 Sepetember 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Type:
relative density
Density:
0.972
Temp.:
20 °C

Results of duplicate determinations of relative density are shown in the following table;

Measurement  Determination 1  Determination 2 
Mass of Pycnometer(g)  21.2263  21.2905 
Mass of Pycnometer and distilled H2O at 20.0 deg C  46.1528  46.619 
Mass of Pycnomter and test material at 20.0 deg C  45.5014  45.9309 
Density of water at 20.0 deg C (kg/m3)  998.20  998.20 
Density (kg/m3)  972.12  971.07 
Relative density  0.972  0.971 

mean relative density: 0.972 and temperature: 20.0 +/- 0.5 deg C

Conclusions:
The relative density of the test material has been determined to be 0.972 at 20.0 ± °C
Executive summary:

The relative density for SiMAA2 was determined using the pycnometer method, Method A3 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).

The relative density of the test material has been determined to be 0.972 at 20.0 ± °C.

Description of key information

The relative density for SiMAA2 was determined using the pycnometer method, Method A3 of Commission Directive 92/69/EEC.

The relative density of the test material has been determined to be 0.972 at 20.0 ± °C.

Key value for chemical safety assessment

Relative density at 20C:
0.972

Additional information