Registration Dossier

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D97
Version / remarks:
Pour point Analysis of crude oils
GLP compliance:
no
Type of method:
pour point
Key result
Melting / freezing pt.:
< -21 °C

Minimum temperature of the pour point test apparatus and its cooling medium is -24 °C. Repeatability of the test at 95% confidence level as per ASTM interlaboratory test program is 3 °C.

Conclusions:
Pouring point <-21 °C
Executive summary:

Standard Test Method for Pour Point of Petroleum Products, ASTM D97 was conducted on Pure Australian sandalwood oil and sandalwood album oil.

The pouring point of the test material is <-21 °C

Description of key information

Standard Test Method for Pour Point of Petroleum Products, ASTM D97 was conducted on Pure Australian sandalwood oil and sandalwood album oil.

The pouring point of the test material is <-21 °C

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-21 °C

Additional information