Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 April 2017 to 19 September 2017
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
BS ISO 13320:2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Identity: Cesium acetate
Appearance: White to light brown powder
Storage conditions: Room temperature (15 to 25°C), desiccated, dark
Batch number: 205071U001
Purity: 100%
Expiry date: March 2018
Date received: 03 November 2016
Mass median aerodynamic diameter:
>= 110 - <= 590 µm
Key result
Percentile:
D10
Mean:
ca. 110 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
see study report
Key result
Percentile:
D50
Mean:
ca. 280 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
see study report
Key result
Percentile:
D90
Mean:
ca. 590 µm
St. dev.:
0
Remarks on result:
other:
Remarks:
see study report
Conclusions:
Cesium acetate was determined to have d(0.1), d(0.5) and d(0.9) values of 110, 280 and 590 μm respectively.
Executive summary:

The purpose of this study was to determine the particle size distribution of the test item, Cesium acetate.

The study was conducted in accordance with accepted principles in order to meet the requirements of REACH Regulation (EU) No 1907/2006 of the European Parliament and of the Council and the Collaborative International Pesticides Analytical Council (CIPAC), Handbook K, 2003 (MT 187).

Cesium acetate was determined to have d(0.1), d(0.5) and d(0.9) values of 110, 280 and 590 μm respectively.

Description of key information

The purpose of this study was to determine the particle size distribution of the test item, Cesium acetate.

The study was conducted in accordance with accepted principles in order to meet the requirements of REACH Regulation (EU) No 1907/2006 of the European Parliament and of the Council and the Collaborative International Pesticides Analytical Council (CIPAC), Handbook K, 2003 (MT 187).

Cesium acetate was determined to have d(0.1), d(0.5) and d(0.9) values of 110, 280 and 590 μm respectively.

Additional information