Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2007-02-13 to 2007-02-15
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study, OECD guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Version / remarks:
AND Directive CE - methode C19 et OCDE 121
Deviations:
yes
Remarks:
The deviation was not considered to have compromised the validity or integrity of the study.
GLP compliance:
yes (incl. QA statement)
Remarks:
2005-12-16
Type of method:
HPLC estimation method
Media:
soil

Test material

Constituent 1
Reference substance name:
-
EC Number:
446-990-1
EC Name:
-
Molecular formula:
C5H11O5 [C6H10O5]1.45 and C5H10O4 and C5H12O5
IUPAC Name:
2-(hydroxymethyl)oxolane-3,4-diol; 5-{[2,3,4,5-tetrahydroxy-6-(xenoniooxy)hexyl]oxy}pentane-1,2,3,4-tetrol; pentane-1,2,3,4,5-pentol
Details on test material:
batch number: 173 JG-1 (at receipt), 173 JG1 (on the analytical certificate)
description: at receipt, gel
on anlaytical cetrificate yellox hard wax
received: 2006-12-12
storage conditions: at room temperature
purity: 99.7%
hydrosolubility 674 g/L at 20°C
expiry date: 2008-01-03
Radiolabelling:
no

Study design

Test temperature:
22 +/- 1°C

HPLC method

Details on study design: HPLC method:
chromatographic conditions
pump: 118 (Beckman)
Mobile phase (degazed): methanol 55%, water 45%
pH of mobile phase: 5.5
Flow rate: 1 mL/min
Column: Lichrospher 5 CN (Interchim)
particle size: 5um, length= 250mm
inner diameter: 4mm
Detector: Refractive Index Detector 2414 (Waters)
Injector: Spectra system AS3000 (TSP)
Injected volume: 50 uL
Software: Empower 2 (Waters)
Analysis time: 5 min

Batch equilibrium or other method

Computational methods:
As the retention time of the peak observed for the test item was close to the dead volume and below the retention time of acetanilide, reference item (Koc=1.25), the adsorption coefficient was demonstrated to be such as log Koc<1.25. In addition, when possible, an estimation using a calculation method on the non validated software PCKOC (v1.66) was performed.
The test item is a mixture.
The absortption coefficient of the test item was estimeted on the basis of the highest obtained value.

Results and discussion

Adsorption coefficient
Type:
Koc
Value:
<= 1
Temp.:
22 °C

Applicant's summary and conclusion

Conclusions:
Koc <= 1 according to an OECD test n°121
No further adsorption/desorption test is needed
Executive summary:

The aim of this study was to assess the absorption/desorption coefficient (Koc) of aquaxyl on soil. The estimation was carried out according to the test guidelines described in OECD guideline n° 121and directive 2001/59/EEC, C.19.

HPLC method was performed on an analytical column packed with a cyanopropyl solid phase containing lipophilic and polar moities. As the test item is not ionizable, a test was performed with the following mobile phase: methanol/water (55/45 v/v) at pH5.5

As the retention time of the peak observed for the test item was close to the dead volume and below the retention time of acetanilide, reference item (Koc=1.25), the adsorption coefficient was demonstrated to be such as log Koc<1.25. In addition, when possible, an estimation using a calculation method on the non validated software PCKOC (v1.66) was performed.

The test item is a mixture.

The absortption coefficient of the test item was estimeted on the basis of the highest obtained value.

the Koc of the test item was stated ≤1.