Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 March 1999 to 4 June 1999
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Boiling pt.:
> 360 °C
Atm. press.:
99.73 kPa
Decomposition:
no

The appearance of the test material in the crucibles after conducting the DSC determinations was the same as the test material at the start of the test (brown liquid) - this indicates no decomposition had occurred.

No phase transition occurred.

A calculated value of boiling temperature using an adapted Stein and Brown method gave the boiling temperature to be 773 K (500 °C).

Conclusions:
The boiling point of the test material was determined to be in excess of 633 ± 0.5 K at 99.73 kPa.
Executive summary:

The boiling point of the test material was evaluated in a study which was conducted under GLP conditions and in accordance with the standardised guideline EU Method A.2 using Differential Scanning Calorimetry.

The boiling point of the substance was determined to be in excess of 633 ± 0.5 K at 99.73 kPa.

Description of key information

Boiling point = 360 °C, EU MEthod A.2, Woolley & Mullee (1999)

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
360 °C

Additional information

The boiling point of the test material was evaluated in a study which was conducted under GLP conditions and in accordance with the standardised guideline EU Method A.2 using Differential Scanning Calorimetry.

The boiling point of the substance was determined to be in excess of 633 ± 0.5 K at 99.73 kPa.