Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002
Report date:
2001

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
Tetrahydro-1,3,4,6-tetrakis(hydroxymethyl)imidazo[4,5-d]imidazole-2,5(1H,3H)-dione
EC Number:
226-408-0
EC Name:
Tetrahydro-1,3,4,6-tetrakis(hydroxymethyl)imidazo[4,5-d]imidazole-2,5(1H,3H)-dione
Cas Number:
5395-50-6
Molecular formula:
C8H14N4O6
IUPAC Name:
1,3,4,6-tetrakis(hydroxymethyl)-octahydro-[1,3]diazolo[4,5-d]imidazole-2,5-dione
Test material form:
liquid
Specific details on test material used for the study:
Tetramethylolacetylene urea (47 % aqueous solution)

Results and discussion

Density
Key result
Type:
relative density
Density:
1.215
Temp.:
20 °C

Any other information on results incl. tables

Individual Results

 

 

2nddet.

3rddet.

A

Mass of pycnometer with test item [g]

63.0579

64.1322

B

Mass of pycnometer empty(corrected for air)[g]

32.4084

33.7327

C

Mass of test item (A - B)[g]

30.6495

30.3995

D

Volume of pycnometer [cm3]

25.221

25.010

E

Density of the test item[g/cm3]

1.21524

1.21549

 

Relative density of the test item

mean: 1.2154

The Relative Density of the test item at 20 °C is 1.2154 ± 0.0002.

The measurement uncertainty given corresponds to the range obtained on performing duplicate measurements.

The test item is liquid at room temperature.

Applicant's summary and conclusion