Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-11-01 - 2006-12-14
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study OECD 117, non-GLP. Study performed and documented equivalent to GLP standards. Study according to relevant guideline.
Remarks:
missing temperature
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
Adopted: 13 April 2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Version / remarks:
Directive 92/69/EEC, Official journal L383 A
Deviations:
no
Principles of method if other than guideline:
The partition coefficient (P) is defined as the ratio of the equilibrium concentrations (c) of a dissolved substance in a two-phase system consisting of
two largely immiscible solvents. In the case n-octanol and water:
Pow = C n-octanol / C water
The partition coefficient therefore is the quotient of two concentrations and is usually given in the form of its logarithm to base 10 (log P).
For preliminary information the following calculated value was available (estimation software EPIWIN): log Pow = 3.73

As the HPLC method is applicable when the log Pow value falls within the range 0 to 6, that method was chosen for the determination of the partition
coefficient. HPLC is performed on analytical columns packed with a commercially available solid phase containing long hydrocarbon chains chemically bound onto silica. Chemicals injected onto such a column move along it at different rates because of the different degrees of partitioning between the mobile phase and the hydrocarbon stationary phase. Mixtures of chemicals are eluted in order of their hydrophobicity, with water-soluble
chemicals eluted first and oil-soluble chemicals last, in proportion to their hydrocarbon-water partition coefficient. This enables the relationship
between the retention time on such a (reverse phase) column and the n-octanol / water partition coefficient to be established. The partition
coefficient is deduced from the capacity factor k', given by the expression

t(r) - t(0)
k'= -------------
t(0)

in which, t(r) = retention time of the test substance, and t(o) = average time a solvent molecule needs to pass through the column (dead time).

The test substance was dissolved in n-octanol and water at varying concentrations and analzyed by HPLC. The elution times were used to calculate
the capacity factor k', from which the partition coefficient was deduced.
The linear regression of the log Pow of the reference substances against their log k' had a coefficient of determination of 0.9817.
GLP compliance:
no
Other quality assurance:
other: Tests were carried out according to the requirements of EN ISO 9001
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Refridgerator 5°C
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
4.34
Temp.:
20 °C
Remarks on result:
other: room temperature, assumed to be 20°C

 

Sample No.

TR1

TR2

TR3

 

1)

(min)

(min)

(min)

log k´(x)

  

logPOW (y)

0

0.86

0.85

0.855

 

1

1.48

1.49

1.485

0.737

-0.133

1.7 2)

2

1.97

1.98

1.975

1.31

0.117

2.1 2)

3

2.62

2.63

2.625

2.07

0.316

2.6 2)

4

3.06

3.08

3.07

2.591

0.413

3.2 2)

5

4.32

4.36

4.34

4.076

0.610

3.6 2)

6

5.59

5.63

5.61

5.561

0.745

4.0 2)

7

11

11.18

11.09

11.971

1.078

4.5 2)

8

12.53

12.71

12.62

13.76

1.139

4.8 2)

Test item

8.41

8.836

0.946

4.33 3)

Test item

8.47

8.906

0.950

4.34 3)

Mean value

4.34 3)

 

 

1)Names of the reference compounds see below:

2)Results from the EU test method A.8

3)Interpolated from linearized function log POW= f(log k´) of the calibration data

 

No.              Reference compound

0                  Urea (inert marker)

1                  Acetophenone

2                  Methylbenzoate

3                  Ethylbenzoate

4                  Benzophenone

5                  Phenylbenzoate

6                  Benzylbenzoate

7                  Phenanthrene

8                  Dibenzyl

Conclusions:
The partition coefficient n-octanol / water (Pow) of the test item was determined according to OECD guideline 117 and EU test method A.8 with the
HPLC method. The partition coefficient n-octanol / water (Pow) was reported to be 4.34.
Executive summary:

The partition coefficient n-octanol / water (Pow) of the test item was determined according to OECD guideline 117 and EU test method A.8 with the

HPLC method. The partition coefficient n-octanol / water (Pow) was reported to be 4.34.

NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.

Description of key information

Determined in a valid experimental study, the partition coefficient of n-hexyl metharcrylate is 4.34 (Guideline study OECD 117, non-GLP). This is supported by reported logPow values ranging from 3.5 up to 4.2.

Key value for chemical safety assessment

Log Kow (Log Pow):
4.34
at the temperature of:
20 °C

Additional information

Determined in a valid experimental study, the partition coefficient of n-hexyl metharcrylate is 4.34 (Guideline study OECD 117, non-GLP). This is supported by reported logPow values ranging from 3.5 up to 4.2.