Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 October 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted according to an internationally recognised method, and under GLP. The substance is considered to be adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
Commision Regulation (EC) No 761/2009 of 23 July 2009
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected on 13 and 14 October 2014 / signed on 08 April 2015
Type of method:
static method
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
407 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
528 Pa

Table 4.6/1: Measurement Values

1. Determination
increasing temperature

2. Determination
decreasing temperature

Temp. in °C

Time

Pressure in hPa

Temp. in °C

Time

Pressure in hPa

20.0

11:25

4.2

44.3

14:20

13.3

28.4

11:41

6.2

39.6

14:41

10.8

35.0

11:59

8.2

35.1

15:02

8.6

40.0

12:50

11.2

29.7

15:19

6.7

45.1

13:20

13.8

22.4

15:38

4.6

49.8

14:00

17.6

14.9

16:01

3.1

The calculation results are presented in the following table:

Table 4.6/2: Calculated values for 1/T and log P 

n

Temperature T

Pressure P

Temperature T

1/T

log P

 

°C

hPa

K

1/K

log Pa

1

20.0

4.2

293.15

0.00341122

2.6232

2

28.4

6.2

301.55

0.00331620

2.7924

3

35.0

8.2

308.15

0.00324517

2.9138

4

40.0

11.2

313.15

0.00319336

3.0492

5

45.1

13.8

318.25

0.00314218

3.1399

6

49.8

17.6

322.95

0.00309645

3.2455

7

44.3

13.3

317.45

0.00315010

3.1239

8

39.6

10.8

312.75

0.00319744

3.0334

9

35.1

8.6

308.25

0.00324412

2.9345

10

29.7

6.7

302.85

0.00330196

2.8261

11

22.4

4.6

295.55

0.00338352

2.6628

12

14.9

3.1

288.05

0.00347162

2.4914

The parameters for the linear regression of the graph log (p) vs. 1/T are presented in the following table:

Table 4.6/3.- Linear Regression Parameters

Parameter

Value

Slope

-1978.29022

Intercept

9.357728898

Correlation coefficient r

-0.999062021

Coefficient of determination r2

0.9981

 

Table 4.6/4: Calculated Values for vapour pressure

Parameter

Value

Unit

Vapour Pressure (20 °C)

407

Pa

Vapour Pressure (25 °C)

528

Pa

DISCUSSION

The vapour pressure of the test item was measured using the static method as described in EU method A.4. Twelve pairs temperature/vapour pressure were used to calculate a regression from which vapour pressure at ambient temperature could be estimated.

From the measured values, the vapour pressure of the test item was calculated as 407 Pa at 20.0 °C and 528 Pa at 25 °C. The values of the heating and cooling down phase showed very good correspondence (the coefficient of determination (r2) is greater than 0.95)

Therefore, the result of the study is considered valid.

Conclusions:
The vapour pressure of the test item was calculated as 407 Pa at 20 °C and 528 Pa at 25 °C.(interpolation)
Executive summary:

The vapour pressure of the test item was measured under GLP using the static method as described in EU method A.4 and OECD 104.

Twelve determinations of vapour pressure were performed in a temperature range of 14.9 – 49.8 °C and the pairs of Temperature / Vapour pressure were used to calculate a regression from which vapour pressure at ambient temperature could be interpolated.

The vapour pressure of the test item was calculated as 407 Pa at 20 °C and 528 Pa at 25 °C.

Description of key information

The vapour pressure of the test item was calculated as 407 Pa at 20 °C and 528 Pa at 25 °C (interpolation)

Key value for chemical safety assessment

Vapour pressure:
528 Pa
at the temperature of:
25 °C

Additional information

A fully reliable experimental study conducted according to a recognized OECD/EC method and under GLP, is available.

It is considered as a key study and the result is retained as key data for the purpose of CSA.

Note that the result obtained on this kind of substance should be largely influence by small amounts of volatile constituents and these values don't represent the major part of the substance. Therefore the result should be considered with caution when used for subsequent assessment (worst case).