Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 946-888-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- May from 08th to 10th, 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with generally accepted scientific standards and described in sufficient detail
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- flask method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Type:
- log Pow
- Partition coefficient:
- -0.52
- Temp.:
- 20 °C
- pH:
- ca. 8
- Type:
- Pow
- Partition coefficient:
- 0.317
- Temp.:
- 20 °C
- pH:
- ca. 8
- Details on results:
- Quality criteria were met as values of log Pow derived from individual measurements fell within a range of ± 0.3 log units
- Conclusions:
- logPow: -0.52 at 20 °C and pH ca 8
- Executive summary:
The partition coefficient of the test item was determined using shake-flask method, in accordante with the method and procedures outlined into the OECD guideline 107. The concentration in the aqueous and octanol phases was determined by HPLC-UV/Vis validate method.
The experiments were carried out applying volume ratios and quantities of the test substance depending on expected partition and the LOQ of the analytical method in both phases. The maximum concentration in either phase was less than 0.01 mol/l. Three parallel tests were carried out: in the first, the calculated volume ratio was applied, in the second, this ratio was divided by two and in the third, this ratio was multiplied by two.
Three replicate samples were prepared at all solvent ratios. The separation of the two phases was achieved by centrifugation at 20 °C and the pH of aqueous phases was measured.
The partition coefficient (Pow) of test item was determined to be 0.3169 ± 0.0701 (95 % confidence interval) at 20 °C and pH ca. 8, which corresponds to log Pow of -0.52 using the shake flask method.
Quality criteria were met as values of log Pow derived from individual measurements fell within a range of ± 0.3 log units.
Conclusion
logPow: -0.52 at 20 °C and pH ca 8
Reference
Partition coefficient measured for Test Item
Ratio of solvents (n-Octanol : water) | Partition coefficient | pH conditions | ||||
Pow | Mean | Log Pow | Mean | pH | Mean | |
01:01 | 0.3998 | 0.3938 | -0.40 | -0.40 | 7.83 | 7.84 |
0.3885 | -0.41 | 7.91 | ||||
0.3933 | -0.41 | 7.77 | ||||
01:02 | 0.3773 | 0.3591 | -0.42 | -0.45 | 8.27 | 8.27 |
0.3513 | -0.45 | 8.26 | ||||
0.3488 | -0.46 | 8.28 | ||||
02:01 | 0.2106 | 0.1976 | -0.68 | -0.70 | 7.48 | 7.5 |
0.1901 | -0.72 | 7.51 | ||||
0.1921 | -0.72 | 7.50 | ||||
Mean all±95 % confidence interval | 0.3169±0.0701 | - | -0.52 | - |
Results of the determination of the test item concentrations
Ratio of solvents (n-Octanol:water) | Measured concentration of Test Item (µg/ml) | pH | Measured concentration of Test Item (µg/ml) | ||
In Aqueous phase | Mean | In n-Octanol phase | Mean | ||
01:01 | 144.64 | 145.45 | 7.83 | 58.54 | 58.15 |
146.25 | 57.76 | ||||
149.53 | 148.68 | 7.91 | 58.04 | 57.76 | |
147.82 | 57.48 | ||||
145.26 | 146.32 | 7.77 | 59.14 | 57.55 | |
147.39 | 55.96 | ||||
Mean |
146.82 | 7.84 | 57.82 | ||
Measured test item µg |
1101.11 | - | 433.63 | ||
Total nominal quantity of test item |
1487.2 µg | ||||
Total quantity of test item |
1534.7 µg | Recovery: 103 % | |||
01:02 | 108.46 | 110.71 | 8.27 | 43.18 | 41.77 |
112.96 | 40.36 | ||||
112.95 | 114.54 | 8.26 | 40.03 | 40.23 | |
116.13 | 40.43 | ||||
115.97 | 114.79 | 8.28 | 39.84 | 40.04 | |
113.61 | 40.25 | ||||
Mean |
113.35 | 8.27 | 40.68 | ||
Measured test item µg |
1133.48 | - | 203.41 | ||
Total nominal quantity of test item |
1487.2 µg | ||||
Total quantity of test item | 1336.9 µg | Recovery: 90 % | |||
02:01 | 206.85 | 207.11 | 7.48 | 44.01 | 43.63 |
207.36 | 43.25 | ||||
213.78 | 214.01 | 7.51 | 40.16 | 40.67 | |
214.25 | 41.19 | ||||
207.13 | 209.50 | 7.5 | 39.85 | 40.25 | |
211.87 | 40.65 | ||||
Mean |
210.21 | 7.5 | 41.52 | ||
Measured test item µg |
1051.03 | - | 415.17 | ||
Total nominal quantity of test item |
1487.2 µg | ||||
Total quantity of test item |
1466.2 µg | Recovery: 99 % |
Description of key information
logPow: -0.52 at 20 °C and pH ca 8
Key value for chemical safety assessment
- Log Kow (Log Pow):
- -0.52
- at the temperature of:
- 20 °C
Additional information
OECD 107 - shake flask method
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.