Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
Version / remarks:
2008
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
Version / remarks:
1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-bromo-4-chloro-1-(propan-2-yl)benzene
EC Number:
696-543-1
Cas Number:
1369828-32-9
Molecular formula:
C9H10BrCl
IUPAC Name:
2-bromo-4-chloro-1-(propan-2-yl)benzene

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, non-adapted
Duration of test (contact time):
28 d
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption

Results and discussion

% Degradationopen allclose all
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
7 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
14 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
21 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
not readily biodegradable
Conclusions: