Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 May 2016 to 12 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Remarks on result:
no flash point according to standard method

RESULTS

- Results of the flash point determination are shown in Table 1 (below).

 

TABLE 1 – RESULTS OF FLASH POINT DETERMINATION

Test temperature (°C)

Observations

25.0

No flash

30.0

No flash

35.0

No flash

40.0

No flash

45.0

No flash

50.0

No flash

55.0

No flash

60.0

No flash

65.0

No flash

70.0

No flash

75.0

No flash

75.0 (fresh sample)

No flash

80.0

No flash

85.0

No flash

90.0

No flash

95.0

No flash

100.0 (fresh sample)

Result not stated

105.0

No flash

110.0

No flash

115.0

No flash

120.0

No flash

125.0

No flash

130.0

No flash

135.0

No flash

140.0

No flash

145.0

No flash

150.0

No flash

150.0 (fresh sample)

No flash

155.0

No flash. The flame self-extinguished.

160.0

A blue flame spread across the sample cup.

160.0 (fresh sample)

No flash. The flame self-extinguished.

165.0 (fresh sample)

No flash. The flame self-extinguished.

170.0 (fresh sample)

No flash. The flame self-extinguished.

175.0 (fresh sample)

No flash. The flame self-extinguished. The test item was boiling.

171.0 (fresh sample)

No flash. The flame self-extinguished. No signs of boiling.

172.0 (fresh sample)

No flash. The flame self-extinguished. No signs of boiling.

173.0 (fresh sample)

No flash. The flame self-extinguished. The test item was boiling.

173.0 (fresh sample)

No flash. The flame self-extinguished. The test item was boiling.

171.0 (fresh sample)

No flash. No signs of boiling.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item was determined not to have a flash point below its boiling temperature.
Executive summary:

GUIDELINE

The determination was carried out using a closed cup flash point tester and a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 (30 May 2008).

RESULTS

The test item was determined not to have a flash point below its boiling temperature.

Description of key information

The test item was determined not to have a flash point below its boiling temperature (EU Method A.9).

Key value for chemical safety assessment

Additional information

GUIDELINE

The determination was carried out using a closed cup flash point tester and a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 (30 May 2008).

RESULTS

The test item was determined not to have a flash point below its boiling temperature.