Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
equivalent or similar to guideline
Guideline:
other: internal method based on official guideline
Version / remarks:
internal method based on official guideline
Deviations:
not specified
Principles of method if other than guideline:
The sample was dispersed, stirred and ultrasonicated prior the analytical characterisation by light scattering.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
ca. 13.579 µm
Remarks on result:
other: Sonicated for 2 minutes
Percentile:
D50
Mean:
ca. 177.549 µm
Remarks on result:
other: Sonicated for 2 minutes
Percentile:
D90
Mean:
ca. 419.752 µm
Remarks on result:
other: Sonicated for 2 minutes
Conclusions:
The particle size distribution was measured by light scattering and the results are D10=13.579 µm, D50= 177.549 µm and D90= 419.752 µm.
Executive summary:

The particle size distribution was measured by light scattering and the results are D10=13.579 µm, D50= 177.549 µm and D90= 419.752 µm.

Description of key information

D10= 13.579  µm
D50= 177.549 µm
D90= 419.752 µm

Additional information

The particle size distribution was determined by light scattering and resulted to have the following parameters D10=13.579 µm, D50= 177.549 µm and D90= 419.752 µm.