Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, available as unpublished report, no restrictions, fully adequate for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
yes (incl. QA statement)
Remarks:
Siemens AG, Prozess-Sicherheit, D-65926 Frankfurt am Main, Germany
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
3-[(2-hydroxyethyl)amino]propanol
EC Number:
242-978-3
EC Name:
3-[(2-hydroxyethyl)amino]propanol
Cas Number:
19344-29-7
Molecular formula:
C5H13NO2
IUPAC Name:
3-[(2-hydroxyethyl)amino]propan-1-ol
Details on test material:
- Name of test material (as cited in study report): 3-(2-Hydroxyethylamino)-1-propanol
- Physical state: Colourless clear liquid
- Analytical purity: 99.2 g/100 g (1H-NMR); 98.9 g/100 g (titration)
- Lot/batch No.: 74568175L0
- Expiration date of the lot/batch: January 29, 2016
- Storage condition of test material: Room temperature (10 - 30 °C)

Results and discussion

Flash point
Flash point:
156.5 °C
Atm. press.:
1 013.3 hPa

Any other information on results incl. tables

Preliminary test

Weight / g

Flash point / °C measured

Atmospheric pressure / hPa

Flash point / °C corrected

72.47

160.5

1009.1

160.6

The data point was determined with a heating rate of 8.5 K/min, as proposed in DIN EN ISO 2719.

Main test

Weight / g

Flash point / °C measured

Atmospheric pressure /hPa

Flash point / °C corrected

71.10

156.5

1009.2

156.6

71.25

156.5

1013.5

156.5

71.47

156.5

1012.2

156.5

The data points were determined with a heating rate of 5.5 K/min.

The flash point corrected to 1013.3 hPa was rounded down with an accuracy of 0.5 °C: 156.5 °C.