Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-03-10 to 2010-04-19
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup method
Flash point:
207 °C
Atm. press.:
1 013 hPa
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2011-12-07
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93/07
GLP compliance:
no
Type of method:
closed cup
Flash point:
> 100 °C
Atm. press.:
102.3 kPa

Average of two measurements, in each case result reported as > 100 °C at 102.3 kPa.

Description of key information

207 °C at 1013 hPa (EU A.9, closed cup)

Key value for chemical safety assessment

Additional information

In another closed cup determination (ASTM D93/07) the flash point is confirmed as > 100 °C.