Registration Dossier

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied

Description of key information

The substance does not have oxidising properties.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

The test substance is incapable of reacting exothermically with combustible materials and does not contain oxygen or halogen atoms chemically bonded to nitrogen or oxygen.

Justification for classification or non-classification

Based on the available information, classification on oxidising properties is not warranted in accordance with EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation No. (EC) 1272/2008.