Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 April 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO 2592 (Determination of flash and fire points - Cleveland open cup method)
Version / remarks:
ASTM Standard D92-12b,, Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester”, ASTM International, West Conshohocken, PA
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
open cup
Key result
Remarks on result:
no flash point up to 100°C
Remarks:
BOILED @ 104
Interpretation of results:
GHS criteria not met
Conclusions:
In an ASTM D921 study Reaction products of monoethanolamine and boric acid 1:3 dd not produce a flashpoint up to 100°C.

Description of key information

In an ASTM D921 study Reaction products of monoethanolamine and boric acid 1:3 dd not produce a flashpoint up to 100°C.

Key value for chemical safety assessment

Additional information