Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-11-10
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D446/07
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Reference substance name:
Benzene, mono C10-13-alkyl derivs, distn residues, sulfonated
IUPAC Name:
Benzene, mono C10-13-alkyl derivs, distn residues, sulfonated
Constituent 2
Reference substance name:
Hydrocarbons, C16-C20 (even numbered), n-alkanes, isoalkanes, <2% aromatics
Molecular formula:
not available, UVCB
IUPAC Name:
Hydrocarbons, C16-C20 (even numbered), n-alkanes, isoalkanes, <2% aromatics
Details on test material:
- Name of test material (as cited in study report): DABS
- Substance type: Product
- Physical state: liquid
- Lot/batch No.: 53348

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
862
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
639

Any other information on results incl. tables

CALIBRATION

(repeat determination)

SUBSTANCE USED FOR CALIBRATION: 1 -Octanol NQS08003

CALIBRATION TEMPERATURE:25.0 °C / 25.0 °C

KINEMATIC VISCOSITY (THEORY): 8.84 mm2/s / 8.84 mm2/s

VISCOSIMETER CONSTANT: 0.4836 / 0.4836

MEASURED FLOW TIME:18.3 sec / 18.2 sec

KINEMATIC VISCOSITY (EXPERIMENTAL): 8.85 mm2/s / 8.80 mm2/s

MEASUREMENT

(repeat determination)

TEMPERATURE:

20.0 °C / 20.0 °C (40 °C / 40 °C)

VISCOSIMETER CONSTANT: 0.4836 / 0.4836 / 0.4836 / 0.4836

MEASURED FLOW TIME (sec) : 1792.82 / 1771.06 / 1325.32 / 1316.09

KINEMATIC VISCOSITY: 867.01mm2/s / 856.48mm2/s (640.92 mm2/s / 636.46 mm2/s)

KINEMATIC VISCOSITY AVERAGE: 861.75 mm2/s (638.69 mm2/s)

Applicant's summary and conclusion

Executive summary:

Benzene, mono C10-13-alkyl derivs, distn residues, sulfonated is measured according to ASTM D446/07. The viscosity is determind to be 861.75 mm²/s at 20 °C and 638.69 mm²/s at 40 °C.