Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO No., other: ASTM-D93
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): Alkenes, C13-14, hydroformylation products, low boiling
- Substance type: pure Active Substance
- Physical state: liquid
- Storage condition of test material: Ambient condition in the dark

Results and discussion

Flash point
Flash point:
> 100 °C
Atm. press.:
ca. 102.3 kPa

Any other information on results incl. tables

CALIBRATION

REFERENCE MATERIAL: n-tetradecane NQS08005

FLASH POINT OF REFERENCE MATERIAL (THEORY): 109.3°C

FLASH POINT OF REFERENCE MATERIAL (EXPERIMENTAL): 109 °C

MEASUREMENT

TEMPERATURE OF FIRST IGNITION TRIAL: 80 °C

INTERVAL BETWEEN IGNITIONS: 1 °C

ATMOSPHERIC PRESSURE: 102.3 kPa

IGNITION TEMPERATURE AT ATMOSPHERICPRESSURE: >100 °C / >100°C

FLASH POINT (CORRECTED FOR 101.3 KPA): >100 °C / >100°C

FLASH POINT (AVERAGE): >100°C

Applicant's summary and conclusion

Conclusions:
Alkenes, C11-12, hydroformylation products, distn. residues: 174.9 °C at atmospheric pressure.
Executive summary:

Alkenes, C11-12, hydroformylation products, distn. residues is measured according to ASTM D 93. The flash point is determind to be 175 °C at atmospheric pressure.