Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (NFT) without GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: NFT 20-048
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): Alkenes, C13-14, hydroformylation products, low boiling

Results and discussion

Vapour pressureopen allclose all
Temp.:
ca. 20 °C
Vapour pressure:
< 5 Pa
Temp.:
ca. 50 °C
Vapour pressure:
27 Pa

Any other information on results incl. tables

MEASUREMENT

(repeat determination)

TEMPERATURE: 20 °C / 50 °C

VAPOUR PRESSURE (Pa) 1st TEST: < 5 / 26.8

VAPOUR PRESSURE (Pa) 2nd TEST: < 5 / 27.2

AVERAGE VAPOUR PRESSURE (Pa): < 5 / 27.0

Applicant's summary and conclusion

Executive summary: