Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Bioaccumulation: aquatic / sediment

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
bioaccumulation in aquatic species: fish
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Justification for type of information:
Data is from HSDB and Pubchem authoritative database
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
Environmental bioconcentration factor of the test chemical in fish was estimated using a logKow and a regression-derived equation.
GLP compliance:
not specified
Radiolabelling:
not specified
Vehicle:
not specified
Test organisms (species):
other: fish
Route of exposure:
aqueous
Test type:
not specified
Water / sediment media type:
natural water: freshwater
Reference substance (positive control):
not specified
Details on estimation of bioconcentration:
BASIS FOR CALCULATION OF BCF
- Result based on calculated logKow of: 1.83
Key result
Type:
BCF
Value:
7.5 dimensionless
Basis:
whole body w.w.
Calculation basis:
other: BCF value of test chemical was estimated using a logKow and a regression-derived equation.
Remarks on result:
other: Other details not known

According to a classification scheme, the BCF value of test chemical suggests the potential for bioconcentration in aquatic organisms is low.

Validity criteria fulfilled:
not specified
Conclusions:
The estimated BCF (bioaccumulation factor) of test chemical was determined to be 7.5 dimensionless.
Executive summary:

The bioaccumulation study in fish was conducted for estimating the BCF (bioaccumulation factor) value of test chemical. The bioaccumulation factor (BCF) value was calculated using a logKow of 1.83 and a regression-derived equation. The estimated BCF (bioaccumulation factor) value of test chemical in fish was determined to be 7.5 dimensionless, which does not exceed the bioconcentration threshold of 2000, indicating that the test chemical is considered to be non-accumulative in aquatic organisms.

Description of key information

The bioaccumulation study in fish was conducted for estimating the BCF (bioaccumulation factor) value of test chemical (authoritative databases, 2017). The bioaccumulation factor (BCF) value was calculated using a logKow of 1.83 and a regression-derived equation. The estimated BCF (bioaccumulation factor) value of test chemical in fish was determined to be 7.5 dimensionless, which does not exceed the bioconcentration threshold of 2000, indicating that the test chemical is considered to be non-accumulative in aquatic organisms.

Key value for chemical safety assessment

BCF (aquatic species):
7.5 dimensionless

Additional information

Experimental study and various predicted data of the test chemical were reviewed for the bioaccumulation end point which are summarized as below:

 

In an experimental key study from authoritative database (2017),bioaccumulation experiment in fish was conducted for estimating the BCF (bioaccumulation factor) value of test chemical. The bioaccumulation factor (BCF) value was calculated using a logKow of 1.83 and a regression-derived equation. The estimated BCF (bioaccumulation factor) value of test chemical in fish was determined to be 7.5 dimensionless.

 

In a prediction done using the BCFBAF Program of Estimation Programs Interface was used to predict the bioconcentration factor (BCF) of test chemical. The bioconcentration factor (BCF) of test chemical was estimated to be 7.489 L/kg whole body w.w (at 25 deg C).

 

In an another prediction done by using Bio-concentration Factor module (ACD (Advanced Chemistry Development)/I-Lab predictive module, 2017)), Bio-concentration Factor of the test chemical was estimated to be 18.4 at pH range 1-14, respectively.

 

On the basis of above results for test chemical(from authoritative and modelling databases,2017), it can be concluded that the BCF value of test chemical ranges from 7.489 to 18.4, respectively,which does not exceed the bioconcentration threshold of 2000, indicating that the test chemical is not expected to bioaccumulate in the food chain.

 

Waiver statement

In accordance with column 2 of Annex IX of the REACH regulation,testing for this endpointis scientifically not necessary and does not need to be conducted since the test chemicalhas a low potential for bioaccumulation based on logKow ≤ 3.