Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
9.5. – 8.6. 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 D (Ready Biodegradability: Closed Bottle Test)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Cyclohexyl(ethyl)amine
EC Number:
226-733-8
EC Name:
Cyclohexyl(ethyl)amine
Cas Number:
5459-93-8
Molecular formula:
C8H17N
IUPAC Name:
N-ethylcyclohexanamine
Test material form:
other: liquid
Details on test material:
- Name of test material (as cited in study report): N-ethylcyclohexylamine
- Physical state: clear colourless liquid
- Analytical purity: 99.5% (w/w)
- Impurities (identity and concentrations): cyclohexanol 0.22% (w/w), alifatic amines 0.23% (w/w), water 0.07% (w/w)
- Lot/batch No.: 89002001
- Expiration date of the lot/batch: 12/2012
- Storage condition of test material: in original packaging at the fridge

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
sewage, predominantly domestic, non-adapted
Details on inoculum:
INOCULUM
A mixed population of microorganisms obtained from the secondary effluent of the wastewater treatment plant of Pardubice processing predominantly municipal sewage.

PREPARATION OF THE INOCULUM
The fresh collected wastewater was filtered through paper filter. COD was determined and wastewater was aerated till using.

JUSTIFICATION OF THE TEST SYSTEM
The inoculum preparation is in conformity with the recommendations of the test guidelines.
Duration of test (contact time):
0 - 28 d
Initial test substance concentration
Initial conc.:
3.38 - 3.39 mg/L
Based on:
COD
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption
Details on study design:
TEST CONDITIONS
- Mineral medium: preparation of mineral medium in accordance to Method C.4E - Closed Bottle Test, Council Regulation (EC) No. 440/2008, published in O. J. L 142, 2008.
- Inoculated medium: The mineral medium was strongly aerated for 20 min. and let standing for 20 h at the test temperature. The volume of wastewater for the inoculation of mineral medium was chosen 2.0 mL per 1 L of medium. 30 L aerated mineral medium was prepared for the test and before the beginning of the test it was inoculated with 60 mL of modified wastewater. The pH value of medium: 7.4.
- Test temperature: 20+/-1°C
- Illumination: in the dark
- pH adjusted: no

TEST SYSTEM
- Series of bottles for the test:
- 2 x 9 bottles with test substance and inoculated medium
- 2 x 9 bottles with reference substance and inoculated medium for the check of inoculum activity
- 2 x 5 bottles with test and reference substance mixture and inoculated medium for the toxicity test
- 2 x 9 bottles with inoculated medium only for the blank determination

TEST SYSTEM
- Measuring equipment: equipment for the determination of dissolved oxygen

CONTROL AND BLANK SYSTEM
- Inoculum blank: yes, the inoculated mineral medium
- Toxicity control: yes, the test and reference substance mixture

MEASUREMENT:
- analysis for dissolved oxygen by the Winkler method at the zero-time, 3rd, 7th, 10th, 14th, 17th, 21st, 24th and 28th day.
Reference substance
Reference substance:
benzoic acid, sodium salt

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
0.6
Sampling time:
28 d

BOD5 / COD results

BOD5 / CODopen allclose all
Parameter:
COD
Value:
200 other: mg.L-1
Parameter:
BOD5
Value:
9 other: mg.L-1
Results with reference substance:
COD of reference substance: 1.642 mg.mg-1, biodegradation 87% after 28 days.

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
under test conditions no biodegradation observed
Conclusions:
In this 28-day study of ready biodegradability a degradation of 0.6 % of the test substance, N-ethylcyclohexylamine, was attained in the end of study.
Executive summary:

The test substance, N-ethylcyclohexylamine, was tested for the ready biological degradability in Closed Bottle Test.

 

Test performance

The test was performed according to: Method C.4E - Closed Bottle Test, Council Regulation (EC) No. 440/2008, published in O.J.L 142, 2008.

 

The results of biological degradation are related to experimentally determined COD values

of test and reference substance at the beginning of the test.

Owing to the limited water solubility of test substance dosing the dispersion in mineral medium into each bottle was implemented.

Sodium benzoate was used as the reference substance. The dosage was carried out from the stock solution.

COD of the test substance in medium at the beginning of the main test: 3.38 - 3.39 mg.L-1

COD of reference substance in medium at the beginning of the main test: 3.45 mg.L-1

In parallel to the main test the toxicity test was performed.

Based on the test substance contains nitrogen in the chemical composition, the oxidized nitrogen forms were determined and the correction for nitrification was carried out.

The test was performed at temperature of 20 ± 1 °C with the pH values of solutions 7-8 at the beginning of the test.

 

Validity of test

The prescribed validity criteria in the test were fulfilled.

The test substance was not inhibiting for the used inoculum.

Since all criteria of acceptability were met, this study is considered to be valid.