Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011-05-03
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted according to an appropriate test method. It was not compliant with GLP.
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2008
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
76 °C
Atm. press.:
1 013 hPa

 

Test

Measured value (°C)

Corrected value (°C)

1

75

76

2

75

76

Mean value*

76

*The mean value is calculated from test 1 and 2 and rounded to± 0.5°C

Determination of the corrected flash-point:

Tc= T0+ 0.25 x (101.3 – p)

TC= corrected flash point to the standard atmospheric pressure (101.3 kPa)

T0= measured flash point at actual atmospheric pressure

p = actual atmospheric pressure [kPa]

Interpretation of results:
GHS criteria not met
Conclusions:
A flash point value of 76°C at 1013 hPa has been determined for the substance using an appropriate test method but not in compliance with GLP. The result is considered reliable.

Description of key information

Flash Point: 76°C at 1013 hPa (ISO 3679)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
76 °C

Additional information

A measured flash point value of 76°C at 1013 hPa was determined for the registered substance using a rapid equilibrium closed-cup method in accordance with ISO 3679 Test Method. The result is considered to be reliable and is selected as key study.

A measured flash point of 76°C and boiling point of 206°C at 1013 hPa indicate that the substance should not be classified for flammability in accordance with Regulation (EC) No. 1272/2008.