Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Reference substance name:
reaction mass of 4-methoxyphenol and 4-methoxy-cyclohexanone and 4-methoxy-cyclohexanol
EC Number:
947-389-1
Molecular formula:
unspecified
IUPAC Name:
reaction mass of 4-methoxyphenol and 4-methoxy-cyclohexanone and 4-methoxy-cyclohexanol

Results and discussion

Flash point
Flash point:
87.5 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

Initial test: 88.0°C

Main test: Corrected value: 87.7 °C

The corrected flashpoint to the nearest 0.5°C is 87.5 °C