Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Remarks:
The study was conducted according to a recognised guideline, but no experimental details are provided. The substance is considered to be adequately identified, with purity. Therefore validation applies with restrictions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Qualifier:
according to guideline
Guideline:
ISO 3219 (Plastics; polymers/resins in the liquid state or as emulsions or dispersions; determination of viscosity using a rotational viscometer with defined shear rate)
Qualifier:
according to guideline
Guideline:
DIN 53019 Part 1 (Viscometry - Measurement of viscosities and flow curves by means of rotational viscometers - Part 1: Principles and measuring geometry)
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)

Test material

Constituent 1
Chemical structure
Reference substance name:
N-[(thiophen-2-yl)methyl]-1H-pyrazol-5-amine
EC Number:
815-539-4
Cas Number:
1374750-27-2
Molecular formula:
C8H9N3S
IUPAC Name:
N-[(thiophen-2-yl)methyl]-1H-pyrazol-5-amine
Test material form:
liquid

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
9 345
Remarks on result:
other: extrapolated
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
606
Remarks on result:
other: measured

Any other information on results incl. tables

Regression:

n(T) = 10exp(A+(B/(t+C)))

A = -0.829097

B = 291.839

C = 40.804

T (°C) 30 40 50 60 70 80
ŋ (mPa.s) 1962 606 243 116 63,8 38,6

Applicant's summary and conclusion

Conclusions:
Viscous liquid. No potential for Aspiration hazard.
Executive summary:

The dynamic viscosity of the test substance was measured according to ISO3219/DIN53019 standards (listed in OECD 114 guideline), with a rotary viscometer. Measurements were recorded every 10°C between 30 and 60°C, and the regression parameters were determined.

The results, derived from the regression have been calculated to be 606 mPa.s at 40°C, and 9345 mPa.s at 20°C.