Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2013 to January 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well documented guideline study
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Principles of method if other than guideline:
not relevant
GLP compliance:
no
Type of method:
effusion method: vapour pressure balance

Test material

Constituent 1
Reference substance name:
308 AQN
IUPAC Name:
308 AQN
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Vapour pressure
Temp.:
120 °C
Vapour pressure:
< 0 hPa
Remarks on result:
other: The test item showed an unusual behaviour of its vapour pressure, most likely caused by its heterogeneous nature. Therefore it can only be concluded that the vapour pressure is <1 * 10E-4 hPa up to 120 °C.
Transition / decomposition
Transition / decomposition:
no
Transition temp.:
> 450 °C

Any other information on results incl. tables

Table 1: Measured vapour pressures and corresponding temperatures

Temperature / °C       Vapour pressure / hPa

50*                                   2.1 × 10-5

60*                                   ---***

70*                                   ---***

80*                                   ---***

90*                                   7.8 × 10-6

100*                                 1.4 × 10-5

95**                                 1.6 × 10-5

105**                               1.5 × 10-5

110**                               1.1 × 10-5

115**                             1.2 × 10-5

120**                             3.1 × 10-5

*1st measurement

**2nd measurement

***The vapour pressure was below the detection limit of the method.

Applicant's summary and conclusion

Conclusions:
The test item showed an unusual behaviour of its vapour pressure, most likely caused by its heterogeneous nature. Therefore it can only be
concluded that the vapour pressure is <1 * 10E-4 hPa up to 120 °C.
Executive summary:

The vapour pressure of 308 AQN was assessed using the balance method, according to EU Guideline A.4 and OECD Guideline 104.

The test item showed an unusual behaviour of its vapour pressure, most likely caused by its heterogeneous nature. Therefore it can only be concluded that the vapour pressure is <1 * 10E-4 hPa up to 120 °C.