Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
particle size distribution (granulometry)
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
DIN 55992-1 (Determination of a parameter for the dust formation of pigments and extenders - Part 1: Rotation method)
Deviations:
not specified
GLP compliance:
no
Type of method:
rotating drum method
Type of distribution:
volumetric distribution
Remarks on result:
not measured/tested
Remarks on result:
not measured/tested

Dustiness values

   Test 1  Test 2  Mean
 Total dustiness [mg/g]  13.38  8.82  11.1
 Inhalable fraction [mg/g] 5.12   2.59  3.855
 Thoraic fraction [mg/g]  1.26  0.22  0.74
 Respirable fraction [mg/g]  0.51  0.09  0.3

The inhalable fraction was only determined up to an airodynamic diameter of 100 µm.

Conclusions:
Dustiness values
 
 Total dustiness [mg/g]: 11.1
 Inhalable fraction [mg/g]:  3.855
 Thoraic fraction [mg/g]: 0.74
 Respirable fraction [mg/g]: 0.3
The inhalable fraction was only determined up to an airodynamic diameter of 100 µm.
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
no guideline followed
Principles of method if other than guideline:
Laser-Granulometer Cilas 1180 Naß
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
other: D16
Mean:
0.59 µm
Remarks on result:
other: no St. dev. was determined
Percentile:
D50
Mean:
1.02 µm
Remarks on result:
other: no St. dev. was determined
Percentile:
other: D84
Mean:
1.68 µm
Remarks on result:
other: no St. dev. was determined
No.:
#1
Size:
0.04 µm
Distribution:
0.1 %
No.:
#2
Size:
0.1 µm
Distribution:
0.34 %
No.:
#3
Size:
0.3 µm
Distribution:
4.26 %
No.:
#4
Size:
0.5 µm
Distribution:
11.22 %
No.:
#5
Size:
0.7 µm
Distribution:
23.44 %
No.:
#6
Size:
1 µm
Distribution:
48.19 %
No.:
#7
Size:
2 µm
Distribution:
91.38 %
No.:
#8
Size:
4 µm
Distribution:
100 %
Conclusions:
The particle size is ≥ 0.04 µm and ≤ 4 µm. The median particle size D50 of the substance is 1.02 µm.

Description of key information

The particle size distribution is ≥ 0.04 µm and ≤ 4 µm. The median particle size D50 of the substance is 1.02 µm.

Dustiness values:

Total dustiness [mg/g]: 11.1  

Inhalable fraction [mg/g]:  3.855  

Thoraic fraction [mg/g]: 0.74  

Respirable fraction [mg/g]: 0.3

The inhalable fraction was only determined up to an airodynamic diameter of 100 µm.

Additional information