Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 10 November 2016 Experimental completion date: 15 November 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: Testing was conducted using a procedure designed to be compatible with Method N.1 of United Nations Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Sixth revised edition, 2015.
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Appearance/Physical state: Amber colored gelatinous solid
Batch: E00268-014-212
Purity: 100%
Expiry date: 10 June 2018
Storage conditions: Room temperature in the dark
Key result
Remarks on result:
other: The test item melted but failed to ignite during the 2 minutes that the Bunsen flame was applied.

The test item melted but failed to ignite during the 2 minutes that the Bunsen flame was applied.

The result of the preliminary screening test obviated the need to perform the definitive test.

Conclusions:
The test item is not a flammable solid.
Executive summary:

The test item was found to not be a flammable solid using a procedure designed to be compatible with Method N.1 of United Nations Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Sixth revised edition, 2015.

Description of key information

The test item is not a flammable solid

Key value for chemical safety assessment

Additional information

The test item was found to be not a flammable solid using a procedure designed to be compatible with Method N.1 of United Nations Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Sixth revised edition, 2015

The test item melted but failed to ignite during the 2 minutes that the Bunsen flame was applied.

The result of the preliminary screening test obviated the need to perform the definitive test.