Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
8th July 2010 - 8th August 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study was conducted in accordance with international guidelines in a GLP testing laboratory.
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: IEC Publications (1987) - Electrical Apparatus for Expolsive Gas Atmospheres Part 4: Method of Test for Ignition Temperature
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Auto-ignition temperature:
> 400 °C
Atm. press.:
101.16 kPa
Remarks on result:
other: Room temperature: 21.2oC

Results

Test Temperature (° C) Test Volume (µl) Ignition Delay (s) Observations
200 (clean flask) 70 >300 No ignition. Grey fumes were emitted.
250 (clean flask) 70 >300 No ignition. Grey fumes were emitted.
300 70 >300 No ignition. Grey fumes were emitted.
350 70 >300 No ignition. Grey fumes were emitted.
400 (clean flask) 70 >300 No ignition. Grey fumes were emitted.
400 (clean flask) 200 >300 No ignition. Grey fumes were emitted.
400 (clean flask) 400 >300 No ignition. Grey fumes were emitted.
400 (clean flask) 600 >300 No ignition. Grey fumes were emitted.
400 (clean flask) 800 >300 No ignition. Grey fumes were emitted.
400 (clean flask) 1000 >300 No ignition. Grey fumes were emitted.
Conclusions:
The material has been determined not to have an auto-flammibilty temperature below 400 °C.
Executive summary:

The auto-flammability temperature of the test substance (PR-4758) was measured in accordance with international guidelines in a GLP testing laboratory, and the value was determined to be greater than (>) 400 °C.

Description of key information

Auto-flammibility = > 400 °C; EU Method A.15; SP Tremain, SS Atwal (2010).

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
400 °C

Additional information

The auto-flammability temperature of the test substance (PR-4758) was measured in accordance with international guidelines to GLP standards in a GLP testing laboratory. and the value was determined to be greater than (>) 400 °C.