Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
distribution modelling
Type of information:
migrated information: read-across based on grouping of substances (category approach)
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Although not a SIDS end point, this study is considered to be the best study of Koc for these carbon numbers.

Data source

Reference
Reference Type:
publication
Title:
Predicting the sorption of fatty alcohols and alcohol ethoxylates to effluent and receiving water.
Author:
van Compernolle R, McAvoy D, Sherren A, Wind T, Cano M L, Belanger S E, Dorn P B, Kerr K M
Year:
2006
Bibliographic source:
Ecotox. and Environ. Safety, 64(1): 61-74

Materials and methods

Test material

Constituent 1
Chemical structure
Reference substance name:
Pentadecan-1-ol
EC Number:
211-107-9
EC Name:
Pentadecan-1-ol
Cas Number:
629-76-5
Molecular formula:
C15H32O
IUPAC Name:
pentadecan-1-ol
Details on test material:
Linear alcohols labelled with 14-C, radiochemical purity 99%

Results and discussion

Any other information on results incl. tables

Alcohol sorption coefficients showed some time dependence, reaching a plateau by 72 h. C15 was found to be an unexplained outlier. The 72 h 

results were:
        
C       12       14       15       16       18

Kd      3000±    8490±    3080±    23800    78700
          80      920      270     ±3200    ±5400

Koc     17980    50830      -    143000   471000

log Koc   4.25    4.71      -     5.15     5.67

These data (neglecting the C15) can be interpreted as a QSAR in the usual way as:

Log Koc = 0.11 + 0.77 log Kow

R2 = 0.994

The result is in line with typical QSARs of this type.