Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 Jan 2021 to 18 Mar 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Version / remarks:
2016
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
4-[4-[(dimethylamino)methyl]-3-phenyl-1H-pyrazol-1-yl]-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Cas Number:
1903009-55-1
Molecular formula:
C27H30N8O4
IUPAC Name:
4-[4-[(dimethylamino)methyl]-3-phenyl-1H-pyrazol-1-yl]-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
Batch (Lot) Number: I20HD2581
Expiry date: 15 August 2022
Physical Description: Yellow powder
Purity: 97.1%
Purity/Composition correction factor: Yes, correction factor is 1.00

STORAGE CONDITIONS
Storage Conditions: At room temperature

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Final preparation of a solid: prior to use in the study, the test material was dried in a desiccator under vacuum using silicagel as the drying agent at 22.8 ± 0.4°C in dark for 44.8 hours

Results and discussion

Densityopen allclose all
Type:
relative density
Density:
1.32
Temp.:
20 °C
Key result
Type:
density
Density:
1.32 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

The results of the tests on the determination of the density of the test item are given in the table below



































 



Test 1



Test 21



Sample mass (g)



1.9574



1.8525



Sample volume (cm3)



1.4862


1.4866


1.4850


1.4838


1.4836



1.4032


1.4017


1.4057


1.4011


1.4015



Average volume (cm3)



1.4850 ± 0.0012



1.4026 ± 0.0017



Density (g/cm3)



1.318



1.321



Mean Density (g/cm3)



1.32



The individual measurements were obtained with an accuracy of < 0.02 g/cm3. According to the guideline, the density of the test item is given as the mean value.

Applicant's summary and conclusion

Conclusions:
A gas comparison stereopycnometer was used for the determination of the density and relative density of JNJ-73848268-AAA (T003903).
The density of the test item at 20ºC was 1.32 g/cm3 (1.32E3 kg/m3).
The relative density was 1.32.