Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Type of method:
flask method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Temp.:
20 °C
pH:
1.9
Remarks on result:
not determinable because of methodological limitations

The results show that no measurable transfer into the octanol phase took place. Therefore, it can de considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.

Conclusions:
The results show that no measurable transfer into the octanol phase took place. Therefore, it can be considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.
Executive summary:

The results show that no measurable transfer into the octanol phase took place. Therefore, it can be considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.

Endpoint:
partition coefficient
Type of information:
(Q)SAR
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Justification for type of information:
Calculation by EPI Suite KOWWIN v1.67 for CAS nr 590-46-5 (betaine hydrochloride, smiles CN(CL)(C)(C)CC(=O)(O) )
Qualifier:
no guideline required
Principles of method if other than guideline:
The partition coeffcient was predicted based on QSAR (KOWWIN v 1.67)
GLP compliance:
no
Type of method:
calculation method (fragments)
Partition coefficient type:
octanol-water
Key result
Type:
log Pow
Partition coefficient:
-4.93
Remarks on result:
other: Log Pow predicted by QSAR (KOWWIN v1.67). Temperature and pH were not measured.
Details on results:
Log Kow(version 1.67 estimate): -4.93

SMILES : CN(CL)(C)(C)CC(=O)(O)
CHEM : (Carboxymethyl)trimethyl ammonium chloride
MOL FOR: C5 H12 CL1 N1 O2
MOL WT : 153.61
-------+-----+--------------------------------------------+---------+--------
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE
-------+-----+--------------------------------------------+---------+--------
Frag | 3 | -CH3 [aliphatic carbon] | 0.5473 | 1.6419
Frag | 1 | -CH2- [aliphatic carbon] | 0.4911 | 0.4911
Frag | 1 | -COOH [acid, aliphatic attach] |-0.6895 | -0.6895
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001
Const | | Equation Constant | | 0.2290
-------+-----+--------------------------------------------+---------+--------
Log Kow = -4.9274
Conclusions:
The estimated value for Log Kow for the test item is based on Kowwin (v1.67) calculations: -4.93

Description of key information

The results show that no measurable transfer into the octanol phase took place. Therefore, it can be considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.

The estimated value for Log Kow for the test item is based on Kowwin (v1.67) calculations: -4.93

Key value for chemical safety assessment

Log Kow (Log Pow):
-4.93

Additional information