Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Chromium trioleate
EC Number:
244-256-3
EC Name:
Chromium trioleate
Cas Number:
21178-63-2
Molecular formula:
C18 H34 O2 .1/3 Cr
IUPAC Name:
chromium(3+) tris((9Z)-octadec-9-enoate)
Details on test material:
Chrom (III)-oleat
Oleic acid Cr III-salt
Batch No.: 5
Product No.: 78623
Purity: no data

Report of the Analytical Laboratory No.: 99L00034

Sampling and analysis

Analytical monitoring:
no

Test solutions

Vehicle:
no

Test organisms

Test organisms (species):
activated sludge, domestic
Details on inoculum:
The activated sludge inoculum used in this study originated from laboratory wastewater treatment plants fed with municipal sewage. The inoculum was washed, brought to a concentration of 5g/L dry substance and aerated for 24 hours. 50 mL were added to a total volume of 250 mL to obtain a concentration of 1g/L dry substance in the test.

Study design

Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
30 min

Test conditions

Test temperature:
20 +/- 2°C
pH:
before correction: 6.2
after correction: 7.8
after 30 minutes incubation: 7.6
Dissolved oxygen:
Oxygen concentration immediately before measurement: 7.6 mg/L
Nominal and measured concentrations:
The compound was tested at the concentration of 1000 mg/L (nominal).
Details on test conditions:
TEST SYSTEM
- Test vessel: Erlenmeyer-vessel
- Test volume: 250 mL
- Synthetic medium: 8 mL/vessel 100-fold concentration OECD medium
- Duration of the measurement of oxygen consumption: 6-10 min
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol

Results and discussion

Effect concentrationsopen allclose all
Duration:
30 min
Dose descriptor:
EC0
Effect conc.:
>= 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
30 min
Dose descriptor:
other: EC20
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Results with reference substance (positive control):
EC20 (30min) ca. 2 mg/L
EC50 (30min) ca. 8 mg/L
EC80 (30min) ca. 70 mg/L

Any other information on results incl. tables

No significant inhibition of respiration was measured at the tested concentration of 1000 mg/L (nominal).