Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 14 February 2008 and 31 March 2008.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
The work described was performed in compliance with UK GLP standards (Schedule 1, Good Laboratory Practice Regulations 1999 (SI 1999/3106 as amended by SI 2004/0994)). Date of inspection: 21/08/2007. Date of signature: 23/04/2008
Type of method:
pycnometer method

Test material

Constituent 1
Details on test material:
Sponsor's identification :Hatcol 1760
Description : clear colourless slightly viscous liquid
Purity : >99%
Date received : 04 February 2008
Storage conditions :room temperature, in the dark

Results and discussion

Density
Type:
relative density
Density:
0.98
Temp.:
20 °C

Any other information on results incl. tables

Results of duplicate determinations of relative density are shown in the following table:

Table6.1

Measurement

Determination

1

2

Mass of pycnometer (g)

13.2317

13.0104

Mass of pycnometer and distilled water at 19.8ºC (g)

22.9889

22.9857

Mass of pycnometer and test material at 20.0ºC (g)

22.8300

22.8612

Density of water at 19.8ºC (kg/m3)

998.25

998.25

Density (kg/m3)

982

986

Relative density

0.982

0.986

Mean relative density:              0.984
Temperature:                           20.0 ± 0.5ºC

Applicant's summary and conclusion

Conclusions:
The relative density of the test material has been determined to be 0.984 at 20.0 ± 0.5°C.
Executive summary:

Method

The relative density was determined using the pycnometer method, Method A3 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).

Result

The relative density of the test material has been determined to be 0.984 at 20.0 ± 0.5°C.