Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 October 2019 - 31 October 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
GLP study to current guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Test substance name: Isophthalonitrile
Chemical name: 1,3-dicyanobenzene
CAS number: 626-17-5
EC number: 210-933-7
LOT number: JB1906150101
Purity: 99.8 % (w/w %)
Appearance: Off white solid flakes
Manufacture date: 15 June 2019
Expiry date: 15 June 2020
Storage condition: Room temperature (15-25oC. below 70 RH%), protected from humidity
Safety Precautions: Routine safety precautions for unknown materials (lab coat. mask. gloves and safety glasses) were applied to assure personnel health and safety.
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
1.5
Temp.:
25 °C
Remarks on result:
other: pHvalue not stated
Details on results:
The retention time measured for Isophthalonitrile (2.245 min) shows that log Pow of the test item is within the calibrated log Pow range. Based on the regression equation, the log Pow of Isophthalonitrile was calculated as 1.5.
Conclusions:
The retention time measured for Isophthalonitrile (2.245 min) shows that log Pow of the test item is within the calibrated log Pow range. Based on the regression equation, the log Pow of Isophthalonitrile was calculated as 1.5.
Executive summary:

In the course of this study the partition coefficient (log Pow) of Isophthalonitrile was estimated using the HPLC method (OECD 117). The estimated log Pow of the test item was given to be 1.5.

Description of key information

In the course of this study the partition coefficient (log Pow) of Isophthalonitrile was estimated using the HPLC method (OECD 117). The estimated log Pow of the test item was given to be 1.5.

Key value for chemical safety assessment

Log Kow (Log Pow):
1.5
at the temperature of:
25 °C

Additional information