Diss Factsheets

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
hydrolysis
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Guideline 111 (Hydrolysis as a Function of pH)
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
yes
Preliminary study:
Hydrolysis of Iron Glycinate was conducted at 50 ± 0.5°C in buffer pH 4, 7 and 9 buffer solutions for a period of 5 days.
Test performance:
Based on the test results Iron Glycinate was found hydrolytically stable in buffer pH 4, pH 7 and 9
buffers at 50C ± 0.5°C.
Transformation products:
no
pH:
9
Temp.:
50
DT50:
>= 1 yr
Type:
(pseudo-)first order (= half-life)
pH:
7
Temp.:
50 °C
DT50:
> 1 yr
Type:
(pseudo-)first order (= half-life)
pH:
4
Temp.:
50 °C
DT50:
> 1 yr
Type:
(pseudo-)first order (= half-life)
Validity criteria fulfilled:
yes
Conclusions:
On the basis of test results, the test item was not hydrolyzed in buffer pH 4, pH 7 and pH 9 when stored at 50 ± 0.5ºC for 5 days. The test item was considered as hydrolytically stable in buffer pH 4, pH 7 and pH 9 buffers. It concludes that the test item half-life is greater than 1 year (t1/2 >1 Year) in buffer pH 4, pH 7 and pH 9.

Description of key information

On the basis of test results, the test item was not hydrolyzed in buffer pH 4, pH 7 and pH 9 when stored
at 50 ± 0.5ºC for 5 days. The test item was
considered as hydrolytically stable in buffer pH 4, pH 7 and pH 9 buffers. It concludes that the test item
half-life is greater than 1 year (t1/2 >1 Year) in buffer pH 4, pH 7 and pH 9.

Key value for chemical safety assessment

Half-life for hydrolysis:
1 yr
at the temperature of:
50 °C

Additional information