Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1992-01-10 to 1992-01-16
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
not applicable
GLP compliance:
no
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION
- Method: Direct dispersion in water
- Controls: Blank control, positive control
- Evidence of undissolved material: Not specified
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Name and location of sewage treatment plant where inoculum was collected: Severn Trent PLC Sewage Treatment Plant, Belper, Derbyshire
- Method of cultivation: Sample maintained at 21 °C with continous aeration; used on the day of collection
- Preparation of inoculum for exposure: pH buffered to 6.7 with sodium hydroxide; suspended solids level adjusted to 3.9 g/L
Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
3 h
Post exposure observation period:
Not performed
Hardness:
Not specified
Test temperature:
Not specified
pH:
Not specified
Dissolved oxygen:
Not specified
Salinity:
Not applicable
Conductivity:
Not specified
Nominal and measured concentrations:
Nominal: 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: Not specified
- No. of vessels per concentration: 3
- No. of vessels per blank control: 2
- No. of vessels per positive control: 1 per concentration


EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
TEST CONCENTRATIONS
- Range finding study : Yes
- Test concentrations: 1.0, 10, 100, 1000
- Results used to determine the conditions for the definitive study: Yes
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 10 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
No inhibition in blank control observed.
Results with reference substance (positive control):
3-h EC50 = 11.5 mg/L

Table 1: Results for the definitve test

Concentration (mg/L) O2 consumption rates
mg O2/L/min
3 hour contact time
% Inhibition
Control R1 0.40 -
R2 0.48 -
Test 1000 R1 0.47 <7>
1000 R2 0.49 <11>
1000 R3 0.47 <7>
Reference 3.2 0.39 11
32 0.08 82

<increase>

r1 - R2: Replicates R1 - R2

Variation between controls: +/- 9%

Table 2: Results for the preliminary range finding test

Concentration (mg/L) O2 consumption rates
mg O2/L/min
3 hour contact time
% Inhibition
Control R1 0.48 -
R2 0.46 -
Test 1 0.44 6
10 0.45 4
100 0.34 28
1000 0.27 43
Reference 3.2 0.40 15
32 0.06 87

Variation between controls: +/- 2%

Validity criteria fulfilled:
not specified
Conclusions:
In an Activated Sludge Respiration Inhibition Test similar to OECD Guideline 209, the 3-h EC50 of the test item was determined to be > 10 mg/L.
Executive summary:

To assess the toxicity of the test item to aquatic microorganisms, a static Activated Sludge Respiration Inhibition Test similar to OECD Guideline 209. A mixed population of activated sludge microorganisms, obtained from the aeration stage of a sewage treatment plant, was exposed to the limit test item concentration of 1000 mg/L (based on the results of a preliminary range finding study). Test solutions were prepared by direct dispersion of the test item in water. In paralellel, a negative control (2 replicates) and a positive control with the reference substance 3,5 -dichlorophenol was performed. The pH was buffered to 6.7 with sodium hydroxide and the suspended solids level was adjusted to 3.9 g/L. In result, no inhibition was observed in the negative control. The 3-h EC50 for the referece substance was determined to be 11.5 mg/L, confirming the suitability of the test item. The 3-h EC50 of the test item was found to be > 10 mg/L.

Description of key information

In an Activated Sludge Respiration Inhibition Test similar to OECD Guideline 209, the 3-h EC50 of the test item was determined to be > 10 mg/L.

Key value for chemical safety assessment

Additional information

To assess the toxicity of the test item to aquatic microorganisms, a static Activated Sludge Respiration Inhibition Test similar to OECD Guideline 209. A mixed population of activated sludge microorganisms, obtained from the aeration stage of a sewage treatment plant, was exposed to the limit test item concentration of 1000 mg/L (based on the results of a preliminary range finding study). Test solutions were prepared by direct dispersion of the test item in water. In paralellel, a negative control (2 replicates) and a positive control with the reference substance 3,5 -dichlorophenol was performed. The pH was buffered to 6.7 with sodium hydroxide and the suspended solids level was adjusted to 3.9 g/L. In result, no inhibition was observed in the negative control. The 3-h EC50 for the reference substance was determined to be 11.5 mg/L, confirming the suitability of the test item. The 3-h EC50 of the test item was found to be > 10 mg/L.