Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 June, 2005
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Remarks:
Guideline study. Final report not available, draft report not dated nor signed by study director.
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
yes
Remarks:
The quantity of test item used for assay No. 3 of the heat sensitivity test was lower than 60 mm (about 45 mm) due to lack of test item.
Key result
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks on result:
not measured/tested
Key result
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks on result:
not measured/tested
Key result
Parameter:
other: Explosive under influence of flame
Remarks on result:
negative (not further specified)
Key result
Parameter:
other: Explosive (not specified)
Remarks on result:
negative (not further specified)

Heat sensitivity (flame): Six negative assays were recorded: no heat sensitivity was noted with the test item.

Mechanical sensitivity (shock): Six negative assays were recorded. No shock sensitivity was noted with the test item.

Interpretation of results:
non explosive
Conclusions:
The test item was not considered to have explosive properties (heat and mechanical sensitivity) in experimental conditions.
Executive summary:

The explosive properties of Fast Pyrolysis Bio-oil were studied in a guideline study. The test item was not considered to have explosive properties (heat and mechanical sensitivity)

Description of key information

Fast Pyrolysis Bio-oil (BIOTOX-21) was not considered to have explosive properties (heat and mechanical sensitivity) in a guideline study.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

According to classification criteria of CLP regulation ((EC) No 1272/2008), no classification is needed regarding explosive properties.