Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO No., other: DIN 51758
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
67 °C
Atm. press.:
ca. 1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
A flash point of 67 °C was determined for the test item.
Executive summary:

The flash point of the test item was determined according to DIN 51758 "Testing of liquid petroleum products and other combustible liquids; determination of flash point by Pensky-Martens closed tester". A flash point of 67 °C was determined for the test item.

Description of key information

The flash point of the test item was determined according to DIN 51758 "Testing of liquid petroleum products and other combustible liquids; determination of flash point by Pensky-Martens closed tester". A flash point of 67 °C was determined for the test item.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
67 °C