Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 Nov 2011 – 13 Jan 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to EU and OECD methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: European Commission technical guidance document, June 1996
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
adopted in 1981
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Department of Health, UK GLP Monitoring Authority (2011)
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
bis(4-tert-butylphenyl)iodanium; hexafluoro-λ⁵-phosphanuide
EC Number:
620-341-4
Cas Number:
61358-25-6
Molecular formula:
C20H26F6IP
IUPAC Name:
bis(4-tert-butylphenyl)iodanium; hexafluoro-λ⁵-phosphanuide
Details on test material:
- Name of test material (as cited in study report): PF-6
- Physical state: white powder
- Analytical purity: 99.2 %
- Batch No.: 20101020
- Expiration date of the batch: 12 April 2012
- Storage condition of test material: In the dark, at room temperature

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
< 100 µm
Distribution:
50.3 %
Remarks on result:
other: screening test
No.:
#2
Size:
< 10 µm
Distribution:
0.783 %
Remarks on result:
other: cumulative percentage, mean of 3 determinations
No.:
#3
Size:
< 5.5 µm
Distribution:
0.212 %
Remarks on result:
other: cumulative percentage, mean of 3 determinations

Any other information on results incl. tables

Screening test (sieve method)
The results of the sieving procedure are shown in the following table:

 

Measurement

Result

Mass of test item transferred to sieve

1607 g

Mass of test item passed through sieve

8.09 g

Proportion of test item < 100 µm

50.3 %

 

Definitive test (cascade impactor method)

The results of the cascade impactor method determinations are shown as follows:

Determination 1

Collection
Stage

Particle Size Range
Collected (µm)

Mass (g)

 

Pre-sampling

Post-sampling

Difference

Cup 1

>10.0

86.1227

89.1431

3.0204

Cup 2

5.5 to 10.0

85.5586

85.5846

0.0260

Cup 3

2.4 to 5.5

85.9064

85.9109

00045

Cup 4

1.61 to 2.4

85.6891

85.6902

0.0011

Cup 5

0.307 to 1.61

85.8601

85.8606

0.0005

Filter

< 0.307

75.5584

75.5600

0.0016

 

Mass of test item found in artificial throat: 0.06 g.

Total mass of test item recovered from artificial throat, sample cups and filter: 3.1141 g.

 

Determination 2

Collection
Stage

Particle Size Range
Collected (µm)

Mass (g)

 

 

 

Pre-sampling

Post-sampling

Difference

Cup 1

>10.0

86.1232

88.9498

2.8266

Cup 2

5.5 to 10.0

85.5581

85.5744

0.0163

Cup 3

2.4 to 5.5

85.9066

85.9102

0.0036

Cup 4

1.61 to2.4

85.6883

85.6895

0.0012

Cup 5

0.307 to 1.61

85.8601

85.8604

0.0003

Filter

< 0.307

75.5609

75.5622

0.0013

Mass of test item found in artificial throat: 0.15 g.
Total mass of test item recovered from artificial throat, sample cups and filter: 2.9993 g.

 

Determination 3

Collection
Stage

Particle Size Range
Collected (µm)

Mass (g)

 

 

Pre-sampling

Post-sampling

Difference

Cup 1

>10.0

86.1231

88.8464

27233

Cup 2

5.5 to 10.0

85.5584

85.5689

0.0105

Cup 3

2.4 to 5.5

85.9070

85.9101

0.0031

Cup 4

1.61 to2.4

85.6885

85.6898

0.0013

Cup 5

0.307 to 1.61

85.8600

85.8602

0.0002

Filter

< 0.307

75.5631

75.5640

0.0009

Mass of test item found in artificial throat: 0.39 g.
Total mass of test item recovered from artificial throat, sample cups and filter: 3.12939.


Cumulative amounts
The cumulative amounts of test item found in the three determinations for the individual particle size cut-points are shown in the following table:

Particle Size
Cut-point
(µm)

Cumulative Mass (g)

Cumulative Percentage (%)

 

Determination
1

Determination
2

Determination
3

Determination
1

Determination
2

Determination
3

10.0

0.0337

0.0227

0.0160

1.08

0.757

0.511

5.5

0,0077

0.0064

0.0055

0.247

0.213

0.176

2.4

0.0032

0.0028

0.0024

0.103

9.34 x 10-2 

7.67 x 10-2

1.61

0.0021

0.0016

0.0011

6.74 x 10-2

5,34 x 10-2 

3.52 x 10-2 

0.307

0.0016

0.0013

0.0009

5.14 x 10-2

4.33 x 10-2

2.88 x 10-2 

 

The overall cumulative percentage of test item with a particle size less than 10.0 µm and 5.5 µm are shown in the following table:

Particle size

Cumulative Percentage (%)

 

Determination 1

Determination 2

Determination 3

Mean

< 10.0 µm

1.08

0.757

0.511

0.783

< 5.5 µm

0.247

0.213

0.176

0.212

 

Discussion
Too few particles were of a size less than 10.0 µm to allow accurate assessment of the mass median aerodynamic diameter.

Sampling for the cascade impactor determinations was performed by rolling the test item container for approximately 10 minutes then sampled from the top, middle and bottom.

The inhalable fraction is defined as the mass fraction of particles which can be inhaled by nose or mouth, the thoracic fraction is defined as the mass fraction of particles that passes the larynx and the respirable fraction is defined as the mass fraction of particles that reaches the alveoli.

Applicant's summary and conclusion

Conclusions:
The particle size distribution of PF-6 was determined using the sieve method (screening test) and the cascade impactor method (definitive test): 50.3 wt-% had an inhalable particle size < 100 µm, 0.783 wt-% had a thoracic particle size < 10 µm and 0.212 % had a respirable particle size < 5.5 µm.