Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29/05/2020 - 12/08/2020
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Other quality assurance:
other: OECD Principles on Good Laboratory Practice (as revised in 1997), C (97) 186 (Final)
Type of method:
non-equilibrium method
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
ca. 84.5 °C
Atm. press.:
ca. 101.3 kPa

Table No. 1.: Results of determination of flash-point

   1st determination  2nd determination  3rd determination    Average
 Flash-point (°C)  84 86 84  85.3 

Correction of the detected flash-point to normal atmospheric pressure:

 Tc= 85.3 + 0.25 (101.3 – 104.6) = 84.5 °C

 Uncertainty of determination was estimated to 2.5 °Cand was calculated as 2 x SD.

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
Flash-point of test item 3-(isodecyloxy)propylamine (IDOPA) is 84.5 °C. Uncertainty of determination was estimated to 2.5°C and was calculated as 2 x SD.
Executive summary:

The test was performed accroding to the Method A.9., Flash-point, Council Regulation (EC) No. 440/2008, Published in O.J. L 142, 2008.

Testing was performed by Pensky-Martens apparatus according to ČSN EN ISO 2179.

Flash-point of test item Isodecyloxypropylamine (IDOPA) is 84.5 °C.

Uncertainty of determination was estimated to 2.5°C and was calculated as 2 x SD.

Description of key information

The test was performed according to the Method A.9., Flash-point, Council Regulation (EC) No. 440/2008, Published in O.J. L 142, 2008

 

Testing was performed by Pensky-Martens apparatus accordingto ČSN EN ISO 2719.

 

Key value for chemical safety assessment

Flash point at 101 325 Pa:
84.5 °C

Additional information