Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
Flashpoint of low melting point solid
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 January 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D6450 (Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH FLP, Grabner Instruments, Austria.
Key result
Flash point:
> 200 °C
Atm. press.:
96.4 kPa
Remarks on result:
no flash point according to standard method

Preliminary test was performed from 80 to 200 °C with negative result.

The test material was measured in main tests with two parallel.

No flash point was observed during the main tests.

Interpretation of results:
other: Not classified according to EU criteria.
Conclusions:
Under the conditions of the study no flash point was observed up to 200 °C.
Executive summary:

The flash point of the test material was determined in accordance with standardised guidelines EU Method A.9 and ASTM 6450, under GLP conditions.

A MINIFLASH automatic flash point tester was used for the determination.

A preliminary test was performed from 80 to 200°C with negative result. The test material was measured in the main test with two parallel tests.

No flash point was observed during the main tests.

Under the conditions of the study no flash point was observed up to 200°C.

Description of key information

Under the conditions of the study no flash point was observed up to 200°C.

Key value for chemical safety assessment

Additional information

The flash point of the test material was determined in accordance with standardised guidelines EU Method A.9 and ASTM 6450, under GLP conditions. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).

A MINIFLASH automatic flash point tester was used for the determination.

A preliminary test was performed from 80 to 200°C with negative result. The test material was measured in the main test with two parallel tests.

No flash point was observed during the main tests.

Under the conditions of the study no flash point was observed up to 200°C.