Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
GLP compliance:
yes
Type of method:
method according to Siwoloboff
Specific details on test material used for the study:
Test Item Name TYZOR OGT
IUPAC Name Titanium(4+)tetrakis(2-ethyl-3-hydroxyhexan-1-olate)
C.A. Name Information Not Provided by Sponsor
CAS Number 5575-43-9
Batch/Lot Number 334-300153/000012
Analysed Concentration (Provided by Sponsor) 12.92 %
Date of Manufacture September2017
Date of Expiry September2019
Appearance Pale yellow viscous liquid

Storage Condition (at JRF)
Storage Condition :
Protected from light, air and moisture.
Once opened container was kept under nitrogen blanket to prevent decomposition



Key result
Boiling pt.:
ca. 246.47 °C
Atm. press.:
ca. 760 mm Hg

TABLE1: Boiling Point/Boiling RangeValues of TYZOR OGT

Atmospheric Pressure 760 mmHg

Repli-cation

Temperature

of Initiation of Bubble Formation (°C)

Temperature at which Continuous String of Bubbles were Observed (°C)

Mean Boiling Range

 (°C)

Boiling Point

(°C)

Kelvin (K)

R1

244.30

246.50

243.80 – 246.70

246.50

519.65

R2

243.80

246.20

246.20

519.35

R3

244.20

246.70

246.70

519.85

Mean

246.47

519.62

Standard Deviation

0.25

0.25


Typical Calculation

Boiling Point [in Kelvin (K)]=Observed Boiling Point(°C) + 273.15

                                                         =246.50 + 273.15

                                                         = 519.65

Conclusions:
The mean boiling point of TYZOR OGTwas 519.62 ± 0.25 K (246.47 ± 0.25°C) at normal atmospheric pressure (760 mm Hg) was determined by Siwoloboff method.
Executive summary:

The boiling point/boiling rangeof TYZOR OGT was determined using Siwoloboff method.

The boiling point of TYZOR OGTwas 519.65, 519.35 and 519.85 K at normal atmospheric pressure (760 mm Hg).

The mean boiling point of TYZOR OGTwas 519.62 ± 0.25 K (246.47 ± 0.25°C) at normal atmospheric pressure (760 mm Hg) [TABLE1].

The mean boiling range of TYZOR OGT was 243.80 – 246.70 °C at normal atmospheric pressure (760 mm Hg).

Description of key information

The mean boiling point of TYZOR OGT was 519.62 ± 0.25 K (246.47 ± 0.25°C) at normal atmospheric pressure (760 mm Hg) was determined by Siwoloboff method.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
246 °C

Additional information