Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-08-06
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Key result
Percentile:
D10
Mean:
ca. 79.02 µm
Remarks on result:
other: St. dev. not available
Key result
Percentile:
D50
Mean:
ca. 373.8 µm
Remarks on result:
other: St. dev. not available
Key result
Percentile:
D90
Mean:
ca. 705.24 µm
Remarks on result:
other: St. dev. not available
Conclusions:
Particle size distribution of Guanidine Thiocyanate was determined by Laser scattering/diffraction

D10 79.02 µm
D50 373.8 µm
D90 705.24 µm

Description of key information

Particle size distribution of Guanidine Thiocyanate was determined by Laser scattering/diffraction

 

D10 79.02 µm

D50 373.8 µm

D90 705.24 µm

Additional information