Administrative data

Endpoint:
self-heating substances / mixtures
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.4 (Test method for self-heating substances)
GLP compliance:
yes (incl. QA statement)
Remarks:
Hessisches Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz

Test material

Constituent 1
Chemical structure
Reference substance name:
3-(difluoromethyl)-1-methyl-1H-pyrazole-4-carboxylic acid
EC Number:
700-093-4
Cas Number:
176969-34-9
Molecular formula:
C6H6F2N2O2
IUPAC Name:
3-(difluoromethyl)-1-methyl-1H-pyrazole-4-carboxylic acid

Results and discussion

Self-heating substances / mixtures
Key result
Test procedure:
100 mm sample cube at 140°C
Max. temp. reached:
140
Induction time (h):
9
Result:
negative outcome (no effect observed)

Any other information on results incl. tables

For the test in the 10 cm cube at an oven temperature of 140 °C ±2 °C an amount of 733.3 g of the test item was filled in the sample container. The test item temperature reached the oven temperature (141 °C) after approximately 9 hours. After at least 24 hours the test was stopped without detecting exothermal effects. The maximum sample temperature was 139 °C.

After the measurement the mesh wire basket contained approximately 2 wt.% less test item than at the start. The remaining test item showed no visual changes.

Due to the negative result at 140 °C (10 cm cube) the test item had not to be classified as "self-heating substance" in the sense of UN Manual of Tests and Criteria, Method N.4., and had not to be classified as "self-heating substance" according to chapter 2.1 Il of the GHS (CLP) regulations.

Applicant's summary and conclusion