Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Version / remarks:
July 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EU Method B.40 BIS (In Vitro Skin Corrosion: Human Skin Model Test)
Version / remarks:
May 2008 (REG (EC) No. 440/2008)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Bis[O,O-bis(2-ethylhexyl) dithiophosphorato-S,S']dioxodi-μ-thioxodimolybdenum
EC Number:
273-381-6
EC Name:
Bis[O,O-bis(2-ethylhexyl) dithiophosphorato-S,S']dioxodi-μ-thioxodimolybdenum
Cas Number:
68958-92-9
Molecular formula:
C32H68Mo2O6P2S6
IUPAC Name:
Bis[O,O-bis(2-ethylhexyl) dithiophosphorato-S,S']dioxodi-μ-thioxodimolybdenum
Test material form:
liquid

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Justification for test system used:
validated in vitro test model for sequential testing strategy
Vehicle:
unchanged (no vehicle)
Details on test system:
see attached documents "S-930 - Skin corrosion Study Design.pdf"
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 50 µL
- Concentration (if solution): undiluted

NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL

POSITIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL
- Concentration (if solution): 8N KOH
Duration of treatment / exposure:
3 min and 1 hour
Number of replicates:
4 (two for the 3-minute exposure and two for the 1-hour exposure)

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Remarks:
3-min exposure
Value:
93
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Irritation / corrosion parameter:
% tissue viability
Remarks:
1-h exposure
Value:
92
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation

Any other information on results incl. tables

for detailed results see attached document "S-930 - Skin corrosion Results.pdf"

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
no classification according to REGULATION (EC) 1272/2008