Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Hazard for aquatic organisms

Freshwater

Hazard assessment conclusion:
PNEC aqua (freshwater)
PNEC value:
0.005 mg/L
Assessment factor:
1 000
Extrapolation method:
assessment factor
PNEC freshwater (intermittent releases):
0.046 mg/L

Marine water

Hazard assessment conclusion:
PNEC aqua (marine water)
PNEC value:
0 mg/L
Assessment factor:
10 000
Extrapolation method:
assessment factor

STP

Hazard assessment conclusion:
PNEC STP
PNEC value:
0.288 mg/L
Assessment factor:
10
Extrapolation method:
assessment factor

Sediment (freshwater)

Hazard assessment conclusion:
PNEC sediment (freshwater)
PNEC value:
0.079 mg/kg sediment dw
Extrapolation method:
equilibrium partitioning method

Sediment (marine water)

Hazard assessment conclusion:
PNEC sediment (marine water)
PNEC value:
0.008 mg/kg sediment dw
Extrapolation method:
equilibrium partitioning method

Hazard for air

Air

Hazard assessment conclusion:
no hazard identified

Hazard for terrestrial organisms

Soil

Hazard assessment conclusion:
PNEC soil
PNEC value:
0.019 mg/kg soil dw
Extrapolation method:
equilibrium partitioning method

Hazard for predators

Secondary poisoning

Hazard assessment conclusion:
no potential for bioaccumulation

Additional information

The substance is readly biodegradable on the basis of the available data.

Conclusion on classification

Th environmental classification of the test susbtance is based on the results from the followign aquatic toxicity studies:


LC50 (96 h) fish: 4.596 mg/L


EC50 (48 h) Daphnia: 152 mg/L
EC50 (72 h) algae: > 17.5 mg/L
Biodegradability: Readily Biodegradable
Based on the above results the test item meets the following criteria for classification:
Not classified according to Directive 67/548/EEC.


Not classified according to the CLP Regulation 1272/2008 41