Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 21/07/2017 to 28/09/2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
Internationally recognised standard, but not listed in EU guideline; non-GLP. Test substance adequately identified. Considered sufficient for classification purpose. Therefore validation applies, with restrictions.
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D6450-99 Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Specific details on test material used for the study:
- Storage condition of test material: between 15 and 35 ºC, light protected
Key result
Flash point:
200.2 °C
Atm. press.:
ca. 1 atm
Remarks on result:
other: Accuracy: +/- 0.1ºC
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of test substance is above the classification threshold. Therefore it is not considered as a flammable liquid according to CLP criteria.
Executive summary:

The flash point of the test substance was determined according to ASTM closed cup method, with triplicate measurement. The value of 200.2 °C was retained.

Description of key information

200.2 °C (Continuously closed cup tester, ASTM D6450 -99)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
200.2 °C

Additional information

A reliable experimental study, conducted according to ASTM guideline, closed cup method, is available. Despite acceptable restrictions, and non-GLP, it is considered as a key study, and the result is retained as key data.

This study is relevant for the classification regarding flammable properties.