Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-03-14 to 2016-03-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Noack Laboratorien GmbH Käthe-Paulus-Str. 1 31157 Sarstedt Germany
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
1.05
Temp.:
24 °C
pH:
7

Calibration Data of the Reference Items 

Reference item

log Pow

1st Calibration

2nd Calibration

 

 

t [min]

k

Log k

t [min]

k

Log k

2-Butanone

0.3

2.166

2.66

0.424

2.179

2.68

0.428

4-Acetylpyridine

0.5

2.855

3.82

0.582

2.872

3.85

0.585

Aniline

0.9

3.455

4.83

0.684

3.456

4.83

0.684

Acetanilide

1.0

4.387

6.41

0.807

4.415

6.45

0.810

Benzonitrile

1.6

9.309

14.7

1.17

9.381

14.8

1.17

Acetophenone

1.7

11.198

17.9

1.25

11.290

18.1

1.26

Nitrobenzene

1.9

15.685

25.5

1.41

15.762

25.6

1.41

 

Slope, Y-intercept and Correlation Coefficient of the Regression Line 

 

1st Calibration

2nd Calibration

slope

1.642

1.641

Y-intercept

-0.3552

-0.3589

r2

0.9848

0.9842

r

0.9924

0.9921

 

 

Retention Times, Capacity Factors and Partition Coefficients of the Test Item 

 

t [min]

k

Log k

Log Pow

test item

1st Calibration

2nd Calibration

4,855

7,20

0,857

1.05 ± 0.03

1.05 ±0.03

4,866

7,21

0,858

mean

4,861

7,21

0,858

 

Conclusions:
The log Pow of the test item was determined to be 1.05 (24.0 °C).
Executive summary:

The study was conducted in accordance with OECD TG 117 and Regulation (EC) No 440/2008 method A.8 to determine the partition coefficient of the test substance using the HPLC method. Analysis of was carried out by HPLC-DAD with a C18 analytical column. The test item and the reference items were diluted with methanol and HPLC water to mobile phase ratio and injected into the HPLC system. The partition coefficient log Pow of the test item was determined to be log Pow = 1.05 at 24 °C.

Description of key information

The log Pow of the test item was determined to be 1.05 (24.0 °C).

Key value for chemical safety assessment

Log Kow (Log Pow):
1.05
at the temperature of:
24 °C

Additional information

The study was conducted in accordance with OECD TG 117 and Regulation (EC) No 440/2008 method A.8 to determine the partition coefficient of the test substance using the HPLC method. Analysis of was carried out by HPLC-DAD with a C18 analytical column. The test item and the reference items were diluted with methanol and HPLC water to mobile phase ratio and injected into the HPLC system. The partition coefficient log Pow of the test item was determined to be log Pow = 1.05 at 24 °C.