Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2009-09-04 to 2009-12-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ISO 13321 and USP <429>
Deviations:
no
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
>= 224.6 - <= 243.7 µm
St. dev.:
9.6
Key result
Percentile:
D50
Mean:
>= 529.2 - <= 564.8 µm
St. dev.:
17.9
Percentile:
D90
Mean:
>= 1 001 - <= 1 012 µm
St. dev.:
5.5
Conclusions:
The median particle size (d50) of Cyanamid F1000 is 548 µm.
Executive summary:

The particle size distribution (volume distribution) of Cyanamid F1000 was measured by laser diffraction with dry dispersing according to ISO 13321. The d10, d50 and d90 percentile were determined in three measurements to be d10 = 235 µm, d50 = 548 µm and d90 = 1006 µm.

Description of key information

The median particle size (d50) of Cyanamid F1000 is 548 µm.

Additional information

The particle size distribution (volume distribution) of Cyanamid F1000 was measured by laser diffraction with dry dispersing according to ISO 13321. The d10, d50 and d90 percentile were determined in three measurements to be d10 = 235 µm, d50 = 548 µm and d90 = 1006 µm.